• VertiPak™ HLP-SA SPE is mixed-mode, highly cross-linked
Vinylpyrazine-Divinylbenzene Copolymer-
Trimethylaminopropyl,(VPZ-DVBT) polymeric sorbent offering
both strong reversed phase interaction and strong anion-
exchange interaction with interference-free extraction,
compatability with LC-MS or GC-MS.
• Needs no condition solvent, aqueous sample can be loaded
directly to the dry sorbent bed.
• Exhibits very high binding capacity over mixed-mode silica-
C8/SAX sorbent, up to 30% of sorbent weight allowing
larger sample loads or a smaller sorbent bed resulting in
high, reproducible recoveries and less solvent usage.
• Exhibits excellent mass transfer and mechanical strength
for acidic polar compounds in an aqueous sample or a
bioloical fluid sample.
• Typical applications include acidic drugs and metabolites
from biological fluids, environmetal pollutants from water,
drugs of abuse and metabolites from urine e.g. salicylic
acid, ibuprofen, acetaminophen, 11-nor-delta-9-
tetrahydrocannabinol-9-carboxylic acid.
• Tube format is available in 4 tube sizes.
• Tubes are packaged in zip sealing bag protective from
moisture and light.
• Includes a Performance report including the QC results,
lot chromatogram and lot recovery test.
| Chemical structure |

VertiPak™ HLP-SA (Vinylpyrazine-divinylbenzene Copolymer-
Trimethylaminopropyl, VPZ-DVBT) |
| Specifications |
| Phase |
HLP-SA (Vinylpyrazine-Divinylbenzene
Copolymer-Trimethylaminopropyl,VPZ-DVBT) |
Particle Size (µm) |
30-50
|
Pore Size (Å)
|
80-90
|
Surface Area (m2/g) |
700-800 |
Carbon Load (%)
|
- |
Endcap
|
No |
pH Stability |
1-14 |
|